Torque specifications & compatibility.

Proper torque application is essential for the stability, longevity and performance of iCervico components. Values, compatible tools and item numbers for every part of the restoration, in one reference.

Tightening torque

ComponentTightening torque
i-base Ø4.5 mm PCA, cuff heights H1.5 / H2.5 / H3.5 mm35 Ncm
30° angulated i-base Ø4.5 mm PCA35 Ncm
iCervico Healers25 Ncm
AR-sleeve, R-sleeve30 Ncm

Apply the specified torque with a calibrated torque wrench only.

Installing the i-base on the implant

ComponentCompatible tools
i-base Ø4.5 mm PCA, H1.5 / H2.5 / H3.5 mmiCervico Screwdriver Short (18 mm) or Long (25 mm), iCervico Hand Ratchet (PEEK)
30° angulated i-base Ø4.5 mm PCARegular 1.25 mm hex screwdrivers

Installing the prosthesis on the i-base

ComponentCompatible tools
AR-sleeve, R-sleeve, iCervico HealersUBH30 Screwdrivers (L18 / L25 / L32 mm)
Conventional and scannable impression postsIncluded hand-tightened screw

Ordering reference

ComponentVPI item number
i-base / PCA / H1.5 mm / with retention screw5213006652684
i-base / PCA / H2.5 mm / with retention screw5213006652691
i-base / PCA / H3.5 mm / with retention screw5213006652509
i-base / PCA / 30° angulated5213006652493
AR-sleeve / with screw5213006652707
R-sleeve / with screw5213006652714
Retention screw / Ti / M1.6 × 0.355213006652738
UBH30 screw / M1.6 / L5.1 mm5213006652608
Scannable impression post5213006652486
Conventional impression post5213006652479
Dual analog / digital and conventional model5213006652592

Instruments

InstrumentVPI item number
iCervico screwdriver / short 18 mm5213006652554
iCervico screwdriver / long 25 mm5213006652721
Hand ratchet / PEEK5213006652547
UBH screwdriver / L18 mm5213006652561
UBH screwdriver / L25 mm5213006652578
UBH30 handler5213006652462

iCervico Healers

Profile / positionSmallMediumLarge
Anteriors, centeredaS5213006653179aM5213006653193aL5213006653209
Anteriors, offsetaS5213006653391aM5213006653292aL5213006653308
Premolars, centeredpS5213006653186pM5213006653216pL5213006653223
Premolars, offsetpS5213006653407pM5213006653315pL5213006653322
Lower molars, centeredm1S5213006653230m1M5213006653247m1L5213006653254
Lower molars, offsetm1S5213006653339m1M5213006653346m1L5213006653353
Upper molars, centeredm2S5213006653261m2M5213006653278m2L5213006653285
Upper molars, offsetm2S5213006653360m2M5213006653377m2L5213006653384
Cylindrical6 mm52130066531557 mm5213006653162

Healers are single-use. Pricing and availability on request. Confirm compatibility using the current instructions for use.

Before you torque.

Clean components

Confirm all components are free of debris or contamination before torquing.

Verify fit and stability

Ensure proper seating and a stable fit prior to torque application.

Use a calibrated wrench

Apply the specified value with a calibrated torque wrench, never by feel.

Never over-torque

Exceeding the recommended values can cause material fatigue or component damage.

Warnings and precautions

  • Always follow the manufacturer guidelines of the compatible implant system.
  • Reuse of prosthetic screws may affect performance; replace as needed.
  • Check torque stability periodically during follow-up visits.
Every dimension and ordering reference, including these tables, ships in the product catalog.

The complete 2026 catalog covers all components, dimensions and compatibility notes.

Download the catalog (PDF)