i-base
A single digital abutment for all treatment stages. Scan it directly in surgical and prosthetic phases, with no separate scan posts. The chimney-free design closes the marginal micro-gap and limits bacterial infiltration.
The i-base is placed at surgery and never removed again: fewer disconnections, healthier soft tissue, and a fully digital restorative workflow.
From placement to final prosthesis, in clinic and in lab, the system replaces the usual stack of scan posts, temporary abutments and healing caps.

A single digital abutment for all treatment stages. Scan it directly in surgical and prosthetic phases, with no separate scan posts. The chimney-free design closes the marginal micro-gap and limits bacterial infiltration.
Anatomic soft-tissue shaping in three sizes, centered or offset, plus cylindrical 6 and 7 mm options. Rotates freely on the i-base without breaking the digital protocol.

The anti-rotational AR-sleeve seats single units on the quad-surface geometry and doubles as a scan post. The rotational R-sleeve eases the path of insertion for multi-unit prostheses. Both come in long and short versions.

Two M1.6 screws. The standard Ti6Al4V screw secures healers and prostheses. The UBH30 screw, used with the short sleeve, corrects the screw channel up to 30° in a full 360° envelope. Prostheses are tightened to 30 Ncm.

One analog for all i-base options, in conventional and digital workflows, for stone and 3D-printed models.

For single and multiple unit cases, open or closed tray techniques. A scannable version is available.
Prefabricated emergence profiles for anteriors, premolars, and lower and upper molars, each in centered and offset versions the clinician can modify further.




Installed at implant placement or uncovery and tightened to 35 Ncm, then never uninstalled again. The tissue interface is disturbed exactly once.
Orient the iCervico healer freely on the i-base, independent of the implant connection, and tighten it to 25 Ncm. The digital protocol stays intact.
Scan the i-base directly, scan an AR-sleeve or scannable post, or take a conventional open- or closed-tray impression. The healer goes back on between appointments.
Tighten the screw-retained prosthesis to 30 Ncm. The quad-surface bevel seats it with no marginal micro-gap and no mobility.
Design on the real geometry, not an approximation. The iCervico libraries put every component inside your CAD software.
Native teeth and component libraries for digital design platforms keep the scan, design and delivery phases on one uninterrupted file.
Browse the libraries
Every component, dimension and ordering reference in one document, including torque specifications and implant compatibility tables. September 2026 edition, in English and Greek.